Pass your real exam with PracticeMaterial latest Fire-Inspector-II Practice Materials one-time. All the core knowledge of International Code Council Fire-Inspector-II exam practice material are valid and reliable, compiled and edited by the experienced experts team, which can help you to deal the difficulties in the real test and pass the International Code Council Fire-Inspector-II exam certainly.
PracticeMaterial has an unprecedented 99.6% first time pass rate among our customers.
We're so confident of our products that we provide no hassle product exchange.
| Section | Weight | Objectives |
|---|---|---|
| General Inspection Administration | 20% | - Documentation and reporting - Code enforcement processes - Inspection administration procedures |
| Occupancies | 27% | - Occupancy classifications - Assembly, educational, healthcare, and other occupancy inspections - Special occupancy requirements |
| General Provisions for Fire Safety | 36% | - Fire safety requirements based on IFC - Fire protection systems - Means of egress provisions - Building construction types and fire resistance ratings |
| Regulated Materials and Processes | 17% | - Hazardous materials inspection and handling - Explosives and fireworks - Flammable and combustible liquids - LP-gas and other regulated materials |
Question 1
When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.
A. 100
B. 75
C. 150
D. 50
Question 2
Fine magnesium scrap stored in quantities greater than 1,000 cu. ft. shall be separated from all buildings other than those used for magnesium scrap recovery operations by a distance of not less than ___ ft.
A. 250
B. 100
C. 30
D. 50
Question 3
A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds
A. 500
B. 1,000
C. 225
D. 2,500
Question 4
A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.
A. 5
B. 12
C. 3
D. 10
Question 5
An acceptance test for a fire alarm system in a new apartment building should be scheduled after:
A. the system has been installed and operating for one year.
B. the hydrostatic test of the underground main is completed.
C. the contractor verifies full compliance.
D. each zone is completed.
Solutions:
| Question 1 Answer: A | Question 2 Answer: A | Question 3 Answer: A | Question 4 Answer: C | Question 5 Answer: C |