Network Appliance NS0-516 Certification Exam is designed for professionals who want to validate their skills in designing, deploying, and managing NetApp E-Series SAN solutions. NS0-516 exam focuses on SAN design, protocols, installation, troubleshooting, and optimization. NetApp Implementation Engineer SAN Specialist E-Series (NCIE) certification is intended for individuals who have already achieved the NetApp Certified Data Administrator (NCDA) credential and want to specialize their knowledge in the area of E-Series SAN.

 

NEW QUESTION # 12
Your AutoSupport does not automatically send reports to NetApp's ActiveIQ tool.
In this scenario, how do you access the data that would have been sent using the AutoSupport feature?

  • A. Use SANtricity Unified Manager to collect the support data remotely
  • B. Use SANtricity System Manager to manually collect the support data
  • C. Ask NetApp Support to help you to access the data by using special support tools
  • D. Access the event log by using SANtricity System Manager

Answer: B

Explanation:
* Explanation:
* When AutoSupport is not automatically sending reports to NetApp's ActiveIQ tool, you can manually collect the support data using SANtricity System Manager.
* The manual collection involves generating a support bundle that includes all necessary logs and system information.
* This data can then be reviewed locally or sent to NetApp support for analysis if needed.


NEW QUESTION # 13
The decision to use FC or iSCSI on the 5500 Controller with a 4-port 16Gb/s FC or 10Gb/s iSCSI Optical SFP+ HIC (Host Interface Card) can be ___________. (Choose the best answer.)

  • A. based upon the SFP type
  • B. changed at any time by SANtricity
  • C. ignored because both can be used at the same time
  • D. set at the factory, based on the order

Answer: A


NEW QUESTION # 14
A company wants the most scalable host-side connection topology for E-Series systems. In this scenario, which FC topology would satisfy the requirement?

  • A. direct connect
  • B. private loop
  • C. arbitrated loop
  • D. fabric attach

Answer: D


NEW QUESTION # 15
Review the diagram.

Is this cabling correct or incorrect, and why? (Choose the best answer.)

  • A. The cabling is incorrect because it uses the top-down bottom-up cabling method
  • B. The cabling is incorrect because each controller goes to only one stack of disk shelves
  • C. The cabling is correct for the dual stack cabling method
  • D. The cabling is incorrect because the controllers are cabled from the host port.

Answer: C


NEW QUESTION # 16
Which type of caching on E-Series systems should be enabled according to NetApp recommended practices?

  • A. Prefetch
  • B. Write mirroring
  • C. Write
  • D. Read

Answer: B


NEW QUESTION # 17
Click the Exhibit button.

Referring to the exhibit, which SAS connector is supported on the NetApp E2800 E-Series family?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 18
You help a customer diagnose a performance issue on an E-Series storage system. You decide to measure the amount of data that is being handled over the span of an hour.
In this scenario, what are you measuring?

  • A. throughput
  • B. IOPS
  • C. I/O alignment
  • D. parity

Answer: A

Explanation:
* Definition of Throughput: Throughput refers to the amount of data transferred from or to the storage system over a specific period. It is measured in units such as MB/s or GB/s.
* Relevance to Performance Diagnosis: When diagnosing performance issues on an E-Series storage system, measuring throughput over an hour helps determine the data handling capacity of the system.
This metric can reveal whether the system is processing data efficiently or if there are bottlenecks.
* Methodology: Tools within the SANtricity System Manager can be used to monitor and log throughput, providing insights into the performance characteristics and potential areas needing optimization.
References:
* NetApp E-Series SANtricity System Manager documentation on performance monitoring
* NetApp Implementation Engineer - SAN Specialist - E-Series manuals


NEW QUESTION # 19
Which expansion shelf and E-Series model pairing is correct?

  • A. DE5600 and E5660
  • B. DE5600 and E2724
  • C. DE5600 and E2712
  • D. DE5600 and E5612

Answer: B


NEW QUESTION # 20
Click the Exhibit button.

Referring to the exhibit, what is the total number of ALUA paths from the host to a volume on the EF280?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
* Understand ALUA Path Configuration:
* Step:Review the exhibit to determine the paths between the host and the EF280.
* Reason:ALUA (Asymmetric Logical Unit Access) provides multiple paths for redundancy and load balancing.
* Count the Paths:
* Observation:Each controller has two ports connected to two separate FC switches, and the host is connected to each switch, providing two paths per controller.
* Calculation:2 controllers x 2 paths per controller = 4 total ALUA paths.
References:
* NetApp EF280 System Documentation
* NetApp ALUA Configuration Guide


NEW QUESTION # 21
In the storage manager client, what are host groups? (Choose the best answer.)

  • A. Two or more disk devices joined together
  • B. A custom group of virtual machine hosts
  • C. Volumes linked to update at the same time
  • D. Two or more servers that host localcache.
  • E. A set of I/O hosts with access to the same set of volumes.

Answer: B


NEW QUESTION # 22
Which item can be downloaded concurrently with controller firmware? (Choose the best answer.)

  • A. Drive firmware
  • B. SANtricity software
  • C. ESM firmware
  • D. NVSRAM

Answer: D


NEW QUESTION # 23
Which file contains the configuration for a multipath driver for FC on Linux systems?

  • A. /etc/multipath.conf
  • B. /opt/multipath/multipath.cnf
  • C. /etc/kernel/mp.conf
  • D. /etc/dm-multipath.conf

Answer: A


NEW QUESTION # 24
Which two steps are required to enable multifactor authentication on an E-Series system? (Choose two.)

  • A. Test SSO login
  • B. Configure LDAP
  • C. Configure In-Band Management
  • D. Map roles

Answer: B,D

Explanation:
To enable multifactor authentication (MFA) on an E-Series system, follow these steps:
* Map roles (C):Role mapping is necessary to define the permissions and access levels for different users when MFA is enabled. This ensures that only authorized users can access specific functions and data on the system.
* Configure LDAP (D):LDAP configuration is required for integrating with directory services to manage user authentication and access control. LDAP settings need to be correctly configured to support MFA, allowing the system to authenticate users against an external directory service.
References:
* NetApp E-Series Security Configuration Guide
* SANtricity System Manager User Guide


NEW QUESTION # 25
In which two locations would you find the WWPNs for a Windows host? (Choose two.)

  • A. FC switch
  • B. Windows Device Manager
  • C. host's BIOS
  • D. HBA vendor's utility

Answer: A,D

Explanation:
To find the Worldwide Port Names (WWPNs) for a Windows host, you can check the following locations:
* FC Switch (A):The WWPNs are available in the management interface of the Fibre Channel switch to which the host is connected. By accessing the switch's management tools, you can list all connected devices and their WWPNs.
* HBA Vendor's Utility (D):Host Bus Adapter (HBA) vendors typically provide utilities or management software that allows you to view the properties of the HBAs installed in the system. These utilities will display the WWPNs of the HBA ports.
References:
* NetApp E-Series SANtricity Storage Manager Documentation
* HBA Vendor Documentation (such as from Emulex, QLogic)


NEW QUESTION # 26
An E2812 system, without expansion shelves, is configured with 12 Gb SAS host interface cards (HICS) and is directly connected to a host. However, the host cannot access the volumes.
In this scenario, which two troubleshooting steps should you take? (Choose two)

  • A. Verify that the E2812 SAS CHAP secret is set.
  • B. Verify that the host can ping the E2812 system over the SAS link
  • C. Verify that the E2812 host port SAS link up lights are illuminated
  • D. Verify that the correct SAS ports are in use on the E2812 system

Answer: C,D


NEW QUESTION # 27
What are two base host connectivity selections that are provided by the E2800 controller? (Choose two.)

  • A. IB
  • B. FC
  • C. iSCSI
  • D. SAS

Answer: B,C

Explanation:
The E2800 controller supports Fibre Channel (FC) and iSCSI as base host connectivity options.
FC provides high-speed connectivity for SAN environments.
iSCSI allows for IP-based storage networking, facilitating connectivity over existing Ethernet networks.
References: NetApp E2800 Series Hardware Guide, which lists supported host interfaces.


NEW QUESTION # 28
What is the total number of ALUA paths from the host to a volume on the EF280 that is shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 29
An administrator is asked to provision a 1 TB volume to hold non-critical temporary data for a seismic-analysis application. The volume requires the highest possible IOPS.
In this scenario, which configuration would satisfy this requirement?

  • A. RAID 6 Dynamic Disk Pool with a 32 KiB segment size
  • B. RAID 6 Dynamic Disk Pool with a 256 KiB segment size
  • C. RAID 0 volume group with a 32 KiB segment size
  • D. RAID 5 volume group with a 256 KiB segment size

Answer: C

Explanation:
* Understanding the Requirements: The administrator needs to provision a 1 TB volume for non-critical temporary data that requires the highest possible IOPS.
* Non-Critical Data: Since the data is non-critical, redundancy (data protection) is not the primary concern. Therefore, RAID 0, which does not provide redundancy but maximizes performance, is suitable.
* Highest Possible IOPS: RAID 0 is known for providing the highest IOPS compared to other RAID levels because it stripes data across multiple disks, allowing simultaneous read/write operations.
* Segment Size: A smaller segment size (32 KiB) will result in higher IOPS for small random I/O operations, which is typical in seismic-analysis applications.
References: NetApp E-Series SANtricity Storage Manager documentation and performance tuning guidelines.


NEW QUESTION # 30
Which NetApp tool provides information on size, weight, acoustic noise, and power of NetApp E-Series systems?

  • A. Active IQ
  • B. Interoperability Matrix Tool
  • C. Hardware Universe
  • D. Config Advisor

Answer: C

Explanation:
* Explanation:
* The Hardware Universe is a NetApp tool that provides comprehensive information on the size, weight, acoustic noise, and power requirements of NetApp systems, including the E-Series.
* This tool is essential for planning and managing the physical aspects of deploying NetApp hardware in a data center environment.


NEW QUESTION # 31
A customer is running several EF570 systems and uses the ability of the EF-Series systems to run two host protocols at the same time. You are installing a new EF570 that uses the NVMe protocol for a high performance computing application. The controller on-board ports will not connect, but the HIC ports are working fine.
In this scenario, what is the problem?

  • A. There is a cable fault preventing the on-board ports from connecting
  • B. The on-board host ports are disabled
  • C. The switch ports are shut-down
  • D. The on-board ports have the wrong SFPs for the desired network protocol

Answer: D


NEW QUESTION # 32
Which support data file provides a description of all the hardware, logical components, and properties of the storage system?

  • A. Storage-array-profile.txt
  • B. Storage-array-configuration.cfg
  • C. Connection.txt
  • D. Recovery-guru.html

Answer: A


NEW QUESTION # 33
......


Earning the NCIE certification is a valuable credential for IT professionals who work with NetApp E-Series SAN solutions. It can help them advance their careers and increase their earning potential, as well as provide them with the skills and knowledge needed to effectively manage and support these critical storage environments.

 

Certification dumps - NCIE SAN E-Series NS0-516 guides - 100% valid: https://torrentking.practicematerial.com/NS0-516-questions-answers.html